Water system
Middleport Village
EPA ID OH5300112 · Meigs County · 2,446 people served · owned by a local government
Middleport Village treats its own water from Groundwater wells (3 wells).
The system's record
The Ohio Department of Health's fluoridation report (CDC My Water's Fluoride) lists Middleport Village as buying its water from Pomeroy Village; EPA's inventory shows its own sources as primary with Pomeroy Village as an emergency connection. The two records may reflect a blend or a recent switch.
- Active wells
- 3
- Serves
- 2,446 people · Meigs County
- EPA ID
- OH5300112
About this area's water
Did you know
- The name Middleport refers to the town's spot on the Ohio River roughly halfway between Pittsburgh and Cincinnati; the site went by Sheffield, Coalport and Salisbury before that.
- The village keeps a standing back-up water connection to neighboring Pomeroy - and reported in its 2024 CCR that it never had to open it that year.
- Middleport's 2024 gross alpha result, 15.8 pCi/L, came in numerically above the 15 pCi/L MCL, yet the CCR's Violations column for that row reads 'No.'
- The village still runs combined sewers, so heavy rain sends untreated stormwater and sewage into the Ohio River - the problem a 2025 Appalachian Regional Commission grant on Third Street is meant to chip away at.
- Middleport publishes essentially nothing about what water costs: no rate ordinance, no schedule, just a link to a third-party payment portal.
Source: en.wikipedia.orgmiddleportohio.commiddleportohio.com
History5
- 1798Village history dates the original Leading Creek Settlement to 1798, settled by New Englanders and Revolutionary War veterans arriving by flatboat from Marietta, followed by German immigrants.
- 1820sThe village itself was laid out during the 1820s. It carried three earlier names - Sheffield, Coalport and Salisbury - and absorbed nearby settlements including Vinton and Tarker's Landing.
- 1920Population peaks at 3,772, then declines through the century to 2,530 in 2010 and 2,208 in 2020.
- 2024Village operated its three-well groundwater system (Wells #4, #7, #8, all in use) with no violations in any category of the CCR table and a current unconditional License to Operate.
- 2025Environmental assessment for the ARC-funded Third Street Sanitary Sewer Improvements signed Aug. 12, 2025 with a Finding of No Significant Impact; combined FONSI / notice of intent to request release…
Source: middleportohio.comen.wikipedia.orgmiddleportohio.com
Treatment & pressure
How it is treated
Groundwater from three production wells (#4, #7 and #8) in the Ohio River Valley aquifer, all in service. The CCR reports a total chlorine running annual average of 1.066 ppm, confirming chlorination, and disinfection by-products are detected; the report does not otherwise describe the treatment…
Source: middleportohio.com
Water pressure
Not published. The 2024 CCR and the village website give no system pressure figures and no pressure-zone map.
What it costs
Not published. The village homepage, FAQ and water-quality pages carry no water or sewer rate schedule; customers are directed to the AuthorityPay portal…
Source: middleportohio.commiddleportohio.commiddleportohio.com
Water quality & impurities10
| Contaminant | Level | Limit | Year |
|---|---|---|---|
| Nitrate CCR shows range 0.7-4.49 ppm (as printed, the level found exceeds the stated range top). Runoff from fertilizer… | 4.69 ppm | 10 ppm MCL | 2024 |
| Barium Range 0.0515-0.0644. Erosion of natural deposits; discharge of drilling wastes and from metal refineries. | 0.065 ppm | 2.0 ppm MCL | 2024 |
| Total Trihalomethanes (TTHM) Range 11.6-14.3 ppb. By-product of chlorination. | 14.3 ppb | 80 ppb MCL | 2024 |
| Haloacetic Acids (HAA5) Range <2.4-4.8 ppb. By-product of chlorination. | 4.8 ppb | 60 ppb MCL | 2024 |
| Total chlorine (running annual average) Range 1.09-2.19 ppm as printed in the CCR. | 1.066 ppm | MRDL 4 ppm | 2024 |
| Lead (90th percentile) Zero of 10 samples exceeded the action level. | 1.5 ppb | 15 ppb action… | 2024 |
| Copper (90th percentile) Zero of 10 samples exceeded the action level. | 0.151 ppm | 1.3 ppm action… | 2024 |
| Gross alpha / radon Confirmed verbatim in the CCR table: level found 15.8 pCi/L, range 15.8 pCi/L, MCL 15 pCi/L, Violations column 'No'.… | 15.8 pCi/L | 15 pCi/L MCL | 2024 |
| Radium 226-228 Erosion of natural deposits. | 3.62 pCi/L | 5 pCi/L MCL | 2024 |
| PFAS (per- and polyfluoroalkyl… Sampled under Ohio's statewide PFAS Sampling Initiative; the CCR reports detection below the Ohio EPA action level with… | detected below… not stated | Ohio EPA action… | 2024 |
Source: middleportohio.com
EPA compliance record
Lead at the tap: 90th-percentile result 1.1 ppb in 2025 (action level 15 ppb).
EPA health-based violations since 2015:
- 2024Lead and Copper Rule Revisions · lead service line inventory missing or incomplete (a records requirement, not a lead test result) · open
7 violations of any kind logged since 2020: 2 for required testing that was missed or reported late; 4 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records); 1 health-based.
Projects & plans2
Recent and current work
- Water system upgrades - Grant, Beech, Lincoln and South 5th Avenue · 2025
The only public record is an April 2025 service-interruption notice announcing a roughly four-hour shutoff on those streets 'due to water system upgrades.' No…
Source: middleportohio.commiddleportohio.com
Planned or needed
- Third Street Sanitary Sewer Improvements · 2025 · planned
ARC Grant No. 25 OH-22073. Approximately 170 feet of 8-inch sanitary sewer main in the Third Street right-of-way, plus six 6-inch lateral lines totaling 260…
Supply stress
Ohio EPA's source water assessment rates the Middleport well field HIGH SUSCEPTIBILITY to contamination - it is a shallow alluvial aquifer in the Ohio River valley. Quantity is not the constraint: average daily use in 2024 was 140,800 gallons across three wells, and the Pomeroy interconnection was not needed at all during the year. The…
Source: middleportohio.com
Sewers
Sanitary
Village-operated sanitary collection. The 2025 federal environmental assessment for the ARC-funded Third Street project states plainly that 'Middleport has combined sewer and storm collections systems, which causes the combined sewers to often exceed their capacity, especially during heavy rain events. This results in discharges of…
Storm
Not separate. Per the same 2025 environmental assessment, storm collection is combined with the sanitary system, and the combined sewers overflow to the Ohio River in heavy rain. No standalone stormwater utility or fee is published.
Sourcesverified
Compiled from the utility's own reports and public records, then independently re-checked against primary sources.
Main supplier in 1 ZIP code
Serves
Main water supplier in 2 ZIP codes
- 45760 · Middleport67% of residents
- 45620 · Cheshire Township and Cheshire8% of residents
Also present in 1 more ZIP code
- 45769 · Pomeroy0% of residents
Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.
Buys from · Sells to
Middleport Village does not buy water from another system on record; it treats its own source water.
No other system is on record buying water from Middleport Village.
What the records show about Middleport Village
Who runs it
EPA's record describes Middleport Village as owned by a local government. It has 948 service connections and serves 2,446 people.
EPA classes it as a community water system, one that serves the same residents all year.
Its office telephone on EPA's record is 740-992-5571.
Source: EPA Safe Drinking Water Information System (SDWIS), water system record.
How the water is treated
EPA's treatment table registers these steps for Middleport Village: chlorine disinfection.
The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.
Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).
Violations
EPA counts 1 health-based violation for Middleport Village since 2015. Health-based means a contaminant above its legal limit or a required treatment step not carried out. It falls into 1 separate problem (one contaminant or rule in one year); the table lists it.
EPA logs 7 violations of any kind since 2020: 2 for required testing that was missed or reported late; 4 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records); 1 health-based.
| Year | Contaminant or rule | Kind | Measured | Limit | Status in EPA's record |
|---|---|---|---|---|---|
| 2024 | Lead and Copper Rule Revisions | lead service line inventory missing or incomplete (a records requirement, not a lead test result) | not on file | not on file | open |
Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled September 2026).
Lead and copper at the tap
In the sampling period ending December 2025, the 90th-percentile lead result at Middleport Village was 1.1 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027.
The highest result on file is 1.6 ppb, in the period ending December 2023.
EPA has 5 sampling periods on file for Middleport Village since 2016, the first ending in 2017; no period was above 10 ppb.
Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Middleport Village sent EPA, 867 lines are counted.
| Material | Lines |
|---|---|
| Lead | 0 |
| Galvanized, needing replacement | 3 |
| Unknown material | 826 |
| Not lead | 38 |
| All lines | 867 |
Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.
EPA's dashboard status for this inventory: reported all required service line types.
Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.
PFAS
Ohio EPA's own statewide sampling tested 2 plants of Middleport Village (latest sample March 2021). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.
PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.
Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.
Disinfection byproducts
Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.
For TTHM, the average of Middleport Village's samples in 2019, the last year it was sampled, was 6.3 µg/L. The worst yearly average was 14.4 µg/L and the highest single sample was 17.2 µg/L, from 15 samples taken from 2012 to 2019.
For HAA5, the average in the last year sampled was 0 µg/L. The worst yearly average was 9.3 µg/L and the highest single sample was 18.7 µg/L, from 15 samples.
| Byproduct | Limit | Latest yearly average | Worst yearly average | Highest sample | Samples |
|---|---|---|---|---|---|
| TTHM | 80 µg/L | 6.3 µg/L (2019) | 14.4 µg/L | 17.2 µg/L | 15 |
| HAA5 | 60 µg/L | 0 µg/L | 9.3 µg/L | 18.7 µg/L | 15 |
A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).
Nitrate, arsenic and radioactivity
Nitrate: the highest of 67 samples was 8.8 mg/L (as nitrogen) in 2014; in 2019, the last year sampled, the highest was 1.07 mg/L. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.
Arsenic was not detected in 7 samples (limit 10 µg/L).
| Contaminant | Samples | Highest result | Limit | Samples over limit |
|---|---|---|---|---|
| Nitrate (as nitrogen) | 67 | 8.8 mg/L | 10 mg/L | 0 |
| Arsenic | 7 | not detected | 10 µg/L | 0 |
| Combined radium | 1 | not detected | 5 pCi/L | 0 |
Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Solvents and fuels
EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 18 samples each.
| Compound | Limit | Samples | Detected in | Highest result | Samples over limit |
|---|---|---|---|---|---|
| Benzene | 5 µg/L | 18 | 0 of 18 | not detected | 0 |
| Carbon tetrachloride | 5 µg/L | 18 | 0 of 18 | not detected | 0 |
| 1,2-dichloroethane | 5 µg/L | 18 | 0 of 18 | not detected | 0 |
| Trichloroethylene (TCE) | 5 µg/L | 18 | 0 of 18 | not detected | 0 |
| Tetrachloroethylene (PCE) | 5 µg/L | 18 | 0 of 18 | not detected | 0 |
| Vinyl chloride | 2 µg/L | 18 | 0 of 18 | not detected | 0 |
"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Farm chemicals and metals
EPA's file holds results for all nine herbicides and metals it checked. Detected: barium in 7 of 7 samples, highest 83.1 µg/L (limit 2,000). Not detected: atrazine in 5 samples, alachlor in 5 samples, 2,4-D in 3 samples, chromium in 7 samples, cadmium in 7 samples, mercury in 7 samples, selenium in 7 samples, thallium in 7 samples.
| Substance | Kind | Limit | Samples | Detected in | Highest result | Samples over limit |
|---|---|---|---|---|---|---|
| Atrazine | Farm chemical | 3 µg/L | 5 | 0 of 5 | not detected | 0 |
| Alachlor | Farm chemical | 2 µg/L | 5 | 0 of 5 | not detected | 0 |
| 2,4-D | Farm chemical | 70 µg/L | 3 | 0 of 3 | not detected | 0 |
| Chromium | Metal | 100 µg/L | 7 | 0 of 7 | not detected | 0 |
| Cadmium | Metal | 5 µg/L | 7 | 0 of 7 | not detected | 0 |
| Barium | Metal | 2,000 µg/L | 7 | 7 of 7 | 83.1 µg/L | 0 |
| Mercury | Metal | 2 µg/L | 7 | 0 of 7 | not detected | 0 |
| Selenium | Metal | 50 µg/L | 7 | 0 of 7 | not detected | 0 |
| Thallium | Metal | 2 µg/L | 7 | 0 of 7 | not detected | 0 |
Non-detects count as zero in the highest-result column.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Bacteria in the pipes
From 2012 to 2019, 1 of 384 routine total coliform samples taken in the distribution system at Middleport Village tested positive (0.26%); in 2019, the last year on file, 1 of 48 did. E. coli was never found in the 1 sample tested for it.
A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.
Fluoride
The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Middleport Village buys its water from Pomeroy Village, a system that has fluoride from natural sources, but at a level below what is recommended for preventing tooth decay, and does not adjust it. The level it reports is 0.16 mg/L.
EPA's treatment table lists no fluoridation step at Middleport Village.
Measured fluoride: none was detected in 7 samples at the plant's entry points in 2012 to 2019.
The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.
Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.
How well the service area is mapped
EPA estimated the service area of Middleport Village with a computer model rather than drawing it from the utility's map, so its edges are approximate.
Counting the people who live in the ZIP codes it overlaps, this atlas estimates 2,288 residents are inside the boundary, 94% of the 2,446 people Middleport Village reports serving.
The resident count is an estimate from 2020 Census ZIP-code populations, not a count of customers.
Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.
Photograph
On the map
Show this system's territory on the map — 3 ZIP codes in all.
Sources
U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey
EPA's own record for this system: Enforcement and Compliance History report for OH5300112 (EPA ECHO).
Notable facts: en.wikipedia.org, middleportohio.com, middleportohio.com, middleportohio.com
History: middleportohio.com, en.wikipedia.org, middleportohio.com, middleportohio.com
Water quality: middleportohio.com
Planned work: middleportohio.com, middleportohio.com
Water pressure: middleportohio.com, middleportohio.com
Capital projects: middleportohio.com, middleportohio.com
Rates: middleportohio.com, middleportohio.com, middleportohio.com
Sewers: middleportohio.com, middleportohio.com
Treatment: middleportohio.com
Supply stress: middleportohio.com