Water system
Colonial Villa Mhc, Llc
EPA ID OH5000612 · Mahoning County · 450 people served
Colonial Villa Mhc, Llc treats its own water from Groundwater wells (2 wells).
The system's record
- Active wells
- 2
- Serves
- 450 people · Mahoning County
- EPA ID
- OH5000612
About this area's water
Water quality & impurities
EPA compliance record
Lead at the tap: 90th-percentile result 0 ppb in 2025 (action level 15 ppb).
EPA record: no health-based violations since 2015.
2 violations of any kind logged since 2020: 2 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).
Serves
Colonial Villa Mhc, Llc is not mapped to any ZIP code on record.
Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.
Buys from · Sells to
Colonial Villa Mhc, Llc does not buy water from another system on record; it treats its own source water.
No other system is on record buying water from Colonial Villa Mhc, Llc.
What the records show about Colonial Villa Mhc, Llc
Who runs it
EPA's record says Colonial Villa Mhc, Llc has 174 service connections and serves 450 people.
EPA classes it as a community water system, one that serves the same residents all year.
Source: EPA Safe Drinking Water Information System (SDWIS), water system record.
How the water is treated
EPA's treatment table registers these steps for Colonial Villa Mhc, Llc: chlorine disinfection and sand or media filtration.
The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.
Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).
Violations
EPA's record shows no health-based violations for Colonial Villa Mhc, Llc since 2015.
EPA logs 2 violations of any kind since 2020: 2 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).
Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled November 2026).
Lead and copper at the tap
For the sampling period ending December 2025, EPA's record lists the 90th-percentile lead result at Colonial Villa Mhc, Llc as 0 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027. EPA records a result below the lab's reporting level as 0, so this is the result reported, not proof that no home sampled had lead.
The highest result on file is 15 ppb, in the period ending December 2019.
EPA has 9 sampling periods on file for Colonial Villa Mhc, Llc since 2016, the first ending in 2017; 1 of the 9 periods went above 10 ppb.
Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Colonial Villa Mhc, Llc sent EPA, 167 lines are counted.
| Material | Lines |
|---|---|
| Lead | 0 |
| Galvanized, needing replacement | 0 |
| Unknown material | 0 |
| Not lead | 167 |
| All lines | 167 |
Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.
EPA's dashboard status for this inventory: reported all required service line types.
Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.
PFAS
Ohio EPA's own statewide sampling tested 1 plant of Colonial Villa Mhc, Llc (latest sample August 2020). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.
Ohio EPA's current sampling status map lists 1 plant of Colonial Villa Mhc, Llc as sampled, most recently July 2026.
PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.
Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.
Disinfection byproducts
Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.
For TTHM, the average of Colonial Villa Mhc, Llc's samples in 2019, the last year it was sampled, was 5 µg/L. The worst yearly average was 19.1 µg/L and the highest single sample was 19.1 µg/L, from 8 samples taken from 2012 to 2019.
For HAA5, the average in the last year sampled was 0 µg/L. The worst yearly average was 16.4 µg/L and the highest single sample was 16.4 µg/L, from 8 samples.
| Byproduct | Limit | Latest yearly average | Worst yearly average | Highest sample | Samples |
|---|---|---|---|---|---|
| TTHM | 80 µg/L | 5 µg/L (2019) | 19.1 µg/L | 19.1 µg/L | 8 |
| HAA5 | 60 µg/L | 0 µg/L | 16.4 µg/L | 16.4 µg/L | 8 |
A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).
Nitrate, arsenic and radioactivity
Nitrate: the highest of 16 samples was 0.12 mg/L (as nitrogen) in 2016; in 2019, the last year sampled, nitrate was not detected. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.
Arsenic was not detected in 6 samples (limit 10 µg/L).
| Contaminant | Samples | Highest result | Limit | Samples over limit |
|---|---|---|---|---|
| Nitrate (as nitrogen) | 16 | 0.12 mg/L | 10 mg/L | 0 |
| Arsenic | 6 | not detected | 10 µg/L | 0 |
Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Solvents and fuels
EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 12 samples each.
| Compound | Limit | Samples | Detected in | Highest result | Samples over limit |
|---|---|---|---|---|---|
| Benzene | 5 µg/L | 12 | 0 of 12 | not detected | 0 |
| Carbon tetrachloride | 5 µg/L | 12 | 0 of 12 | not detected | 0 |
| 1,2-dichloroethane | 5 µg/L | 12 | 0 of 12 | not detected | 0 |
| Trichloroethylene (TCE) | 5 µg/L | 12 | 0 of 12 | not detected | 0 |
| Tetrachloroethylene (PCE) | 5 µg/L | 12 | 0 of 12 | not detected | 0 |
| Vinyl chloride | 2 µg/L | 12 | 0 of 12 | not detected | 0 |
"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Farm chemicals and metals
EPA's file holds results for 8 of the nine herbicides and metals it checked. Detected: barium in 5 of 6 samples, highest 132 µg/L (limit 2,000). Not detected: atrazine in 4 samples, alachlor in 4 samples, chromium in 6 samples, cadmium in 6 samples, mercury in 6 samples, selenium in 6 samples, thallium in 6 samples.
| Substance | Kind | Limit | Samples | Detected in | Highest result | Samples over limit |
|---|---|---|---|---|---|---|
| Atrazine | Farm chemical | 3 µg/L | 4 | 0 of 4 | not detected | 0 |
| Alachlor | Farm chemical | 2 µg/L | 4 | 0 of 4 | not detected | 0 |
| Chromium | Metal | 100 µg/L | 6 | 0 of 6 | not detected | 0 |
| Cadmium | Metal | 5 µg/L | 6 | 0 of 6 | not detected | 0 |
| Barium | Metal | 2,000 µg/L | 6 | 5 of 6 | 132 µg/L | 0 |
| Mercury | Metal | 2 µg/L | 6 | 0 of 6 | not detected | 0 |
| Selenium | Metal | 50 µg/L | 6 | 0 of 6 | not detected | 0 |
| Thallium | Metal | 2 µg/L | 6 | 0 of 6 | not detected | 0 |
Non-detects count as zero in the highest-result column.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.
Bacteria in the pipes
From 2012 to 2019, 0 of 100 routine total coliform samples taken in the distribution system at Colonial Villa Mhc, Llc tested positive (0%); in 2019, the last year on file, 0 of 12 did. E. coli was never found in the 4 samples tested for it.
A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.
Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.
Fluoride
The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Colonial Villa Mhc, Llc has fluoride from natural sources, but at a level below what is recommended for preventing tooth decay, and does not adjust it. The level it reports is 0.2 mg/L.
EPA's treatment table lists no fluoridation step at Colonial Villa Mhc, Llc.
Measured fluoride: 0.89 mg/L on average at the plant's entry points in 2018 (above the 0.7 mg/L level now recommended and well under the 4 mg/L limit), with 1 of that year's samples below the 0.2 mg/L reporting limit and left out of the average; samples ran from 0.44 to 1.01 mg/L across 6 samples in 2012 to 2019.
The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.
Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.
How well the service area is mapped
EPA drew the service area of Colonial Villa Mhc, Llc from OpenStreetMap.
Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.
On the map
Sources
U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey
EPA's own record for this system: Enforcement and Compliance History report for OH5000612 (EPA ECHO).