Water system

Wellington Village

EPA ID OH4701511 · Lorain County · 4,802 people served · owned by a local government

Charlemont Creek, via Wellington Upground Reservoir
Inland river

Wellington Village treats its own water from Charlemont Creek, via Wellington Upground Reservoir.

The system's record

Charlemont Creek, via Wellington Upground Reservoir
Inland river
Water bodies
Charlemont Creek, Wellington Upground Reservoir
Raw intakes
Wellington Rese
Wellington Charlemont Creek Rese
Serves
4,802 people · Lorain County
EPA ID
OH4701511

About this area's water

Water quality & impurities

EPA compliance record

Lead at the tap: 90th-percentile result 2.4 ppb in 2026 (action level 15 ppb).

EPA health-based violations since 2015:

  • 2017Total trihalomethanes (TTHM) · above the legal limit on average · measured 0.081 MG/L (limit 0.08 MG/L) · returned to compliance

6 violations of any kind logged since 2020: 4 for required testing that was missed or reported late; 2 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).

Present in 1 ZIP code

Serves

No ZIP code has Wellington Village on record as its main water supplier.

Also present in 1 more ZIP code

Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.

Buys from · Sells to

Wellington Village does not buy water from another system on record; it treats its own source water.

No other system is on record buying water from Wellington Village.

What the records show about Wellington Village

Who runs it

EPA's record describes Wellington Village as owned by a local government. It has 1,914 service connections and serves 4,802 people.

EPA classes it as a community water system, one that serves the same residents all year.

EPA's record says it has substantially implemented source water protection under Ohio's program, dating the program from 2025. Its office telephone on EPA's record is 440-647-1545.

Source: EPA Safe Drinking Water Information System (SDWIS), water system record.

How the water is treated

EPA's treatment table registers these steps for Wellington Village: corrosion control, coagulation and settling, chlorine disinfection, fluoridation, granular activated carbon, and sand or media filtration.

The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.

Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).

Violations

EPA counts 1 health-based violation for Wellington Village since 2015. Health-based means a contaminant above its legal limit or a required treatment step not carried out. It falls into 1 separate problem (one contaminant or rule in one year); the table lists it.

EPA logs 6 violations of any kind since 2020: 4 for required testing that was missed or reported late; 2 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).

Health-based violations since 2015, most recent first
YearContaminant or ruleKindMeasuredLimitStatus in EPA's record
2017Total trihalomethanes (TTHM)above the legal limit on average0.081 mg/L0.08 mg/Lreturned to compliance

Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled September 2026).

Lead and copper at the tap

In the sampling period ending June 2026, the 90th-percentile lead result at Wellington Village was 2.4 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027.

The highest result on file is 17 ppb, in the period ending December 2020.

EPA has 14 sampling periods on file for Wellington Village since 2016, the first ending in 2018; 1 of the 14 periods went above 15 ppb, and 5 above 10 ppb.

Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Wellington Village sent EPA, 1,980 lines are counted.

Service lines in the inventory
MaterialLines
Lead139
Galvanized, needing replacement22
Unknown material132
Not lead1,687
All lines1,980

Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.

EPA's dashboard status for this inventory: reported all required service line types.

Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.

PFAS

EPA's fifth national round of testing (UCMR 5) took 4 samples of the water entering the pipes of Wellington Village in 2024 and measured 29 PFAS. No PFAS was detected, PFOA and PFOS (federal limit 4 ng/L each) among them.

Ohio EPA's own statewide sampling tested 1 plant of Wellington Village (latest sample September 2020). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.

PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.

Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.

Disinfection byproducts

Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.

For TTHM, the average of Wellington Village's samples in 2019, the last year it was sampled, was 54.8 µg/L. The worst yearly average was 74.6 µg/L and the highest single sample was 117.8 µg/L, from 63 samples taken from 2012 to 2019.

For HAA5, the average in the last year sampled was 15.8 µg/L. The worst yearly average was 27.6 µg/L and the highest single sample was 40.5 µg/L, from 63 samples.

Disinfection byproducts in the distribution system
ByproductLimitLatest yearly averageWorst yearly averageHighest sampleSamples
TTHM80 µg/L54.8 µg/L (2019)74.6 µg/L117.8 µg/L63
HAA560 µg/L15.8 µg/L27.6 µg/L40.5 µg/L63

A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).

Nitrate, arsenic and radioactivity

Nitrate: the highest of 95 samples was 0.29 mg/L (as nitrogen) in 2012; in 2019, the last year sampled, the highest was 0.11 mg/L. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.

Arsenic was not detected in 8 samples (limit 10 µg/L).

Nitrate, arsenic and radioactivity in finished water, 2012 to 2019
ContaminantSamplesHighest resultLimitSamples over limit
Nitrate (as nitrogen)950.29 mg/L10 mg/L0
Arsenic8not detected10 µg/L0

Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Solvents and fuels

EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 8 samples each.

Solvents and fuels in finished water, 2012 to 2019
CompoundLimitSamplesDetected inHighest resultSamples over limit
Benzene5 µg/L80 of 8not detected0
Carbon tetrachloride5 µg/L80 of 8not detected0
1,2-dichloroethane5 µg/L80 of 8not detected0
Trichloroethylene (TCE)5 µg/L80 of 8not detected0
Tetrachloroethylene (PCE)5 µg/L80 of 8not detected0
Vinyl chloride2 µg/L80 of 8not detected0

"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Farm chemicals and metals

EPA's file holds results for 8 of the nine herbicides and metals it checked. Detected: barium in 8 of 8 samples, highest 31 µg/L (limit 2,000). Not detected: atrazine, alachlor, chromium, cadmium, mercury, selenium, and thallium, in 8 samples each.

Herbicides and metals in finished water, 2012 to 2019
SubstanceKindLimitSamplesDetected inHighest resultSamples over limit
AtrazineFarm chemical3 µg/L80 of 8not detected0
AlachlorFarm chemical2 µg/L80 of 8not detected0
ChromiumMetal100 µg/L80 of 8not detected0
CadmiumMetal5 µg/L80 of 8not detected0
BariumMetal2,000 µg/L88 of 831 µg/L0
MercuryMetal2 µg/L80 of 8not detected0
SeleniumMetal50 µg/L80 of 8not detected0
ThalliumMetal2 µg/L80 of 8not detected0

Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Bacteria in the pipes

From 2012 to 2019, 0 of 832 routine total coliform samples taken in the distribution system at Wellington Village tested positive (0%); in 2019, the last year on file, 0 of 108 did.

A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.

Fluoride

The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Wellington Village adjusts the fluoride level to the recommended level for preventing tooth decay.

EPA's treatment table lists fluoridation among the steps at Wellington Village.

Measured fluoride: 1.06 mg/L on average at the plant's entry points in 2019 (in the range dentists aim for); samples ran from 0.72 to 3.2 mg/L across 8 samples in 2012 to 2019.

The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.

Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.

Lithium

Lithium was not detected in 4 UCMR 5 samples at Wellington Village, last sampled in 2024 (the method reports from 9 µg/L).

Lithium is not regulated. EPA's draft health reference level is 10 µg/L, and it occurs naturally in deep groundwater, so well systems in the northwest run highest.

Source: EPA UCMR 5 occurrence data (final release, August 2026), samples from 2023 to 2025.

Algal toxins

Ohio EPA tests for microcystin, a toxin that harmful algal blooms can release, in raw water at the intake and in treated water.

At the intake, microcystin was detected 6 times in 182 raw-water samples, across 2 bloom seasons (2017 to 2026); the highest raw-water result was 0.959 µg/L on July 18, 2017. The highest raw-water result since 2024 was 0.243 µg/L.

Microcystin was never detected in treated water (108 samples).

In all, 290 samples from 2016 to 2026, the latest on August 25, 2026.

Microcystin results
WaterSamplesDetectionsHighest result
Raw water, at the intake18260.959 µg/L
Treated water1080not detected

The ten-day advisory levels for treated water are 0.3 µg/L for children under six and 1.6 µg/L for everyone else. Any detection at the intake triggers more frequent testing until two clean weeks.

Source: Ohio EPA public water system harmful algal bloom monitoring, 2016 to present (HAB data, fetched September 2026).

How well the service area is mapped

EPA estimated the service area of Wellington Village with a computer model rather than drawing it from the utility's map, so its edges are approximate.

Counting the people who live in the ZIP codes it overlaps, this atlas estimates 5,192 residents are inside the boundary, 108% of the 4,802 people Wellington Village reports serving.

The resident count is an estimate from 2020 Census ZIP-code populations, not a count of customers.

Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.

On the map

Show this system's territory on the map — 1 ZIP code in all.

Sources

U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey

EPA's own record for this system: Enforcement and Compliance History report for OH4701511 (EPA ECHO).

Wellington Village's own pages: villageofwellington.com, snoflo.org

Quick answers

Where does Wellington Village get its water?

Wellington Village treats its own water from Charlemont Creek, via Wellington Upground Reservoir.

How many people does Wellington Village serve?

Wellington Village serves about 4,802 people.

Who owns Wellington Village?

Wellington Village is owned by a local government.

Cite this page

Cite this page as:

Cracked Buckeye, "Wellington Village · OH4701511", https://crackedbuckeye.com/water/OH4701511/, built 2026-10-31, accessed [date].

How to cite · Report a correction · Built 2026-10-31