Water system

Northwestern W and SD - Sr 108

EPA ID OH3539214 · Henry County · 267 people served · owned by a local government

Maumee River (with Wauseon reservoirs as backup/blend storage)
Inland river

Northwestern W and SD - Sr 108 buys its water from Napoleon City.

The system's record

Maumee River (with Wauseon reservoirs as backup/blend storage)
Inland river
Northwestern W and SD - Sr 108 buys its water from Napoleon City. Napoleon City treats water from Maumee River (with Wauseon reservoirs as backup/blend storage).
Water bodies
Maumee River
Raw intakes
Wauseon MG Reservoir
Maumee River
Serves
8,858 people · Henry County
EPA ID
OH3500811

About this area's water Napoleon City

Historic postcard of the Maumee River near Napoleon, Ohio, the city's water source
Historic postcard of the Maumee River near Napoleon, Ohio, the city's water sourcePhoto: This file was contributed to Wikimedia Commons by Columbus Metropolitan Library , Public domain · Wikimedia Commons
Did you know
  • Napoleon's plant pumped 388 million gallons of raw Maumee River water uphill to the Wauseon reservoir in 2025 - and the pipe can be reversed to pull that stored water back by gravity when the river is unusable, which is…
  • The city's water plant is one of fewer than ten in Ohio using ultraviolet disinfection, added as part of the 2015-2018 conversion to reverse-osmosis membrane softening.
  • Campbell's largest soup plant is in Napoleon, turning out more than 619 million cans of soup, 678 million containers of V8 and 136 million jars of Prego and Pace a year.
  • A July 2026 fertilizer and ammonia spill upstream on Huston Creek killed an estimated 18,000-20,000 fish along about 11 miles of the Maumee - the same river the city drinks from - after bacteria consuming the ammonia…

Source: napoleonohio.comnapoleonohio.comthecampbellscompany.com

History6
  • 1992City installed its current Maumee River raw-water intake facility on West Riverview Ave.
  • 1997-1998$3.8 million wastewater plant expansion raised peak hydraulic capacity to 7.5 MGD.
  • 20102.5 million-gallon equalization basin and UV disinfection units added at the wastewater plant to capture and treat wet-weather/combined-sewer flow.
  • 2015-2018Three-year, $17.8 million rehabilitation converted the lime-soda softening plant to a nanofiltration/reverse-osmosis membrane softening facility with UV disinfection; completed fall 2018.
  • 2021-2025Multi-year, roughly $12 million renovation of the wastewater treatment plant (new headworks building, third primary settling tank, recirculation building and pumps, screw presses) completed…
  • 2026A July liquid-fertilizer (ammonia) release into Huston Creek in Flatrock Township, followed by failure of containment dams on July 11, killed an estimated 18,000-20,000 fish over about 11 miles of…

Source: napoleonohio.comnapoleonohio.comwtol.com

Treatment & pressure

How it is treated

Surface water from a Maumee River intake. Pretreatment with sodium permanganate and carbon in contact basins; coagulation with aluminum chlorohydrate; four-stage vertical flocculation; sedimentation with plate settlers; rapid sand filters; 1-micron cartridge filters; nanofiltration and…

Source: napoleonohio.comnapoleonohio.com

Water pressure

Not published. System storage is two underground clearwells (150,000 and 1,000,000 gallons) plus a north tower (750,000 gallons) and a south tower (200,000 gallons), with three…

Source: napoleonohio.com

What it costs

$12.93 per 1,000 gallons

Typical household bill about $66 a month for water.

Codified Ordinance 931.07 (Ord. 086-20, passed 2-1-21), rate steps effective through the 2024 schedule, which the code library shows as current: inside-corporation commodity…

Source: codelibrary.amlegal.comnorthwestsignal.net

Water quality & impurities10
ContaminantLevelLimitYear
Total Trihalomethanes (TTHM)
range of detections 22.90-78.6 ppb; no violation, but the highest single result is close to the standard
60.93 ppb80 ppb MCL2025
Haloacetic Acids (HAA5)
range printed as 6.2-15.8 ppb; no violation
16.08 ppb60 ppb MCL2025
Nitrate
range 0.028-6.85 ppm; peak is about two-thirds of the standard, reflecting Maumee River farm runoff
6.85 ppm10 ppm MCL2025
Atrazine
range 0-0.64 ppb; runoff from row-crop herbicide
0.64 ppb3 ppb MCL2025
Fluoride
range 0.96-1.12 ppm; added for dental health
1.12 ppm4 ppm MCL2025
Barium
range 0-0.030 ppm
0.030 ppm2 ppm MCL2025
Total chlorine
range 1.37-1.72 ppm
1.55 ppm4 ppm MRDL2025
Copper (90th percentile)
range 0-0.041 ppm; 0 of 20 sites above the action level
0.021 ppm1.3 ppm action…2025
Lead (90th percentile)
0 of 20 sites above the action level
<2 ppb15 ppb action…2025
Turbidity
highest recorded 0.11 NTU; 100% of monthly samples met the limit
0.11 NTU0.3 NTU in 95%…2025

Source: napoleonohio.com

EPA compliance record · Northwestern W and SD - Sr 108

Lead at the tap: 90th-percentile result 0 ppb in 2025 (action level 15 ppb).

EPA record: no health-based violations since 2015.

EPA compliance record · Napoleon City (treats the water)

Lead at the tap: 90th-percentile result 0 ppb in 2025 (action level 15 ppb).

EPA record: no health-based violations since 2015.

Projects & plans3

Recent and current work

  • Water treatment plant conversion to reverse-osmosis/nanofiltration membrane softening with UV · $18 million · 2015-2018 · completed
    Three-phase rehabilitation of the former lime-soda softening plant; cost reported at the 2019 unveiling.
  • Wastewater treatment plant 2.5 MG equalization basin, 30 MGD screw pump station, 10 MGD UV disinfection and… · 2010 · completed
    Ohio EPA-mandated wet-weather storage that allows combined-sewer overflow to receive primary-equivalent treatment and UV rather than going straight to the…
  • Wastewater treatment plant renovation (headworks building, third primary settling tank, recirculation… · $12 million · 2021-2025 · completed
    Construction began June 2021; cost reported by local press (Northwest Signal); the article itself was rate-limited during verification, so treat the figure as…

Source: wtol.comstantec.comnorthwestsignal.net

Supply stress

Ohio EPA treats all Ohio surface water as highly susceptible to contamination, and Napoleon's CCR says the drinking water source protection area contains agriculture, septic systems, oil and gas activity, combined sewer overflows, wastewater discharges, roadways and railways. The practical exposure is upstream events on the Maumee: the…

Source: napoleonohio.comnorthwestsignal.netdam.assets.ohio.gov

Sewers

Sanitary

City wastewater treatment plant at 735 E. Washington St., built 1958 and rehabilitated in 1982, expanded in 1997-98 for $3.8 million. Average daily flow 2.6 MGD, maximum daily 4.7 MGD, peak hydraulic capacity 7.5 MGD. Treatment is screening, primary settling, two 55-foot trickling-filter biotowers, three final settling tanks (761,240…

Storm

Partly combined: the city's west and south sides have combined sewers, and Napoleon files an annual combined sewer overflow public notification report with Ohio EPA. The 2.5 MG equalization basin with integrated 10 MGD UV lets overflow be treated instead of…

Source: napoleonohio.comnapoleonohio.comstantec.com

Sourcesverified

Compiled from the utility's own reports and public records, then independently re-checked against primary sources.

Present in 1 ZIP code

Serves

No ZIP code has Northwestern W and SD - Sr 108 on record as its main water supplier.

Also present in 1 more ZIP code

Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.

Buys from · Sells to

Northwestern W and SD - Sr 108 buys its water from Napoleon City.

No other system is on record buying water from Northwestern W and SD - Sr 108.

What the records show about Northwestern W and SD - Sr 108

Who runs it

EPA's record describes Northwestern W and SD - Sr 108 as owned by a local government. It has 9 service connections and serves 267 people.

EPA classes it as a community water system, one that serves the same residents all year.

Its office telephone on EPA's record is 419-354-9090.

Source: EPA Safe Drinking Water Information System (SDWIS), water system record.

How the water is treated

Northwestern W and SD - Sr 108 buys water that Napoleon City treats first, so the steps that count are the seller's. EPA's treatment table registers these steps for Napoleon City: corrosion control, cartridge filtration, coagulation and settling, chlorine disinfection, dechlorination, iron and manganese removal, fluoridation, powdered activated carbon, reverse osmosis, sand or media filtration, and ultraviolet disinfection.

Northwestern W and SD - Sr 108 adds nothing of its own on that table.

The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.

Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).

Violations

EPA's record shows no health-based violations for Northwestern W and SD - Sr 108 since 2015.

EPA logs no violations of any kind for Northwestern W and SD - Sr 108 since 2020.

Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled September 2026).

Lead and copper at the tap

In the sampling period ending December 2025, the 90th-percentile lead result at Northwestern W and SD - Sr 108 was 0 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027. A result of 0 means at least nine in ten of the homes sampled had no lead detected.

The highest result on file is 4 ppb, in the period ending December 2024.

EPA has 10 sampling periods on file for Northwestern W and SD - Sr 108 since 2016, the first ending in 2017; no period was above 10 ppb.

Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Northwestern W and SD - Sr 108 sent EPA, 8 lines are counted.

Service lines in the inventory
MaterialLines
Lead0
Galvanized, needing replacement0
Unknown material0
Not lead8
All lines8

Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.

EPA's dashboard status for this inventory: reported all required service line types.

Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.

PFAS

The water Northwestern W and SD - Sr 108 buys is treated by Napoleon City, so the results below are Napoleon City's.

EPA's fifth national round of testing (UCMR 5) took 4 samples of the water entering the pipes of Napoleon City in 2024 and measured 29 PFAS.

PFOA and PFOS were not detected, against a federal limit of 4 ng/L each.

The highest PFAS results were PFPeA 9.1 ng/L, PFHxA 7.1 ng/L, and PFBS 3.6 ng/L.

Ohio EPA's own statewide sampling tested 1 plant of Napoleon City (latest sample August 2020). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.

Highest PFOA and PFOS result, UCMR 5
CompoundHighest resultFederal limit
PFOAnot detected4 ng/L
PFOSnot detected4 ng/L

PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.

Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.

Disinfection byproducts

Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.

For TTHM, the average of Northwestern W and SD - Sr 108's samples in 2019, the last year it was sampled, was 53 µg/L. The worst yearly average was 92.9 µg/L and the highest single sample was 124.9 µg/L, from 20 samples taken from 2015 to 2019. A yearly average over 80 is not itself a violation, because compliance is judged site by site.

For HAA5, the average in the last year sampled was 17.8 µg/L. The worst yearly average was 26.1 µg/L and the highest single sample was 33.1 µg/L, from 21 samples.

Disinfection byproducts in the distribution system
ByproductLimitLatest yearly averageWorst yearly averageHighest sampleSamples
TTHM80 µg/L53 µg/L (2019)92.9 µg/L124.9 µg/L20
HAA560 µg/L17.8 µg/L26.1 µg/L33.1 µg/L21

A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).

Nitrate, arsenic and radioactivity

The water Northwestern W and SD - Sr 108 buys is treated by Napoleon City, so the results below are Napoleon City's.

Nitrate: the highest of 374 samples was 9.65 mg/L (as nitrogen) in 2013; in 2019, the last year sampled, the highest was 3.96 mg/L. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.

Arsenic was not detected in 8 samples (limit 10 µg/L).

Nitrate, arsenic and radioactivity in finished water, 2012 to 2019
ContaminantSamplesHighest resultLimitSamples over limit
Nitrate (as nitrogen)3749.65 mg/L10 mg/L0
Arsenic8not detected10 µg/L0

Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water of Napoleon City.

Solvents and fuels

The water Northwestern W and SD - Sr 108 buys is treated by Napoleon City, so the results below are Napoleon City's.

EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 12 samples each.

Solvents and fuels in finished water, 2012 to 2019
CompoundLimitSamplesDetected inHighest resultSamples over limit
Benzene5 µg/L120 of 12not detected0
Carbon tetrachloride5 µg/L120 of 12not detected0
1,2-dichloroethane5 µg/L120 of 12not detected0
Trichloroethylene (TCE)5 µg/L120 of 12not detected0
Tetrachloroethylene (PCE)5 µg/L120 of 12not detected0
Vinyl chloride2 µg/L120 of 12not detected0

"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water of Napoleon City.

Farm chemicals and metals

The water Northwestern W and SD - Sr 108 buys is treated by Napoleon City, so the results below are Napoleon City's.

EPA's file holds results for all nine herbicides and metals it checked. Detected: atrazine in 47 of 68 samples, highest 11 µg/L (limit 3, 7 over); 2,4-D in 1 of 3 samples, highest 0.2 µg/L (limit 70); barium in 4 of 8 samples, highest 15 µg/L (limit 2,000). Not detected: alachlor in 69 samples, chromium in 8 samples, cadmium in 8 samples, mercury in 8 samples, selenium in 8 samples, thallium in 8 samples.

Herbicides and metals in finished water, 2012 to 2019
SubstanceKindLimitSamplesDetected inHighest resultSamples over limit
AtrazineFarm chemical3 µg/L6847 of 6811 µg/L7
AlachlorFarm chemical2 µg/L690 of 69not detected0
2,4-DFarm chemical70 µg/L31 of 30.2 µg/L0
ChromiumMetal100 µg/L80 of 8not detected0
CadmiumMetal5 µg/L80 of 8not detected0
BariumMetal2,000 µg/L84 of 815 µg/L0
MercuryMetal2 µg/L80 of 8not detected0
SeleniumMetal50 µg/L80 of 8not detected0
ThalliumMetal2 µg/L80 of 8not detected0

Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water of Napoleon City.

Bacteria in the pipes

From 2012 to 2019, 0 of 57 routine total coliform samples taken in the distribution system at Northwestern W and SD - Sr 108 tested positive (0%); in 2019, the last year on file, 0 of 12 did.

A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.

Fluoride

The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Northwestern W and SD - Sr 108 buys its water from Napoleon City, a system that adjusts the fluoride level to the recommended level for preventing tooth decay.

EPA's treatment table lists fluoridation among the steps at Napoleon City, which treats the water Northwestern W and SD - Sr 108 buys.

Measured fluoride: 0.97 mg/L on average leaving the plants of Napoleon City, which supplies Northwestern W and SD - Sr 108, in 2019 (in the range dentists aim for); samples ran from 0.8 to 1.15 mg/L across 8 samples in 2012 to 2019.

The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.

Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.

Lithium

Lithium was not detected in 4 UCMR 5 samples at Napoleon City, which supplies Northwestern W and SD - Sr 108, last sampled in 2024 (the method reports from 9 µg/L).

Lithium is not regulated. EPA's draft health reference level is 10 µg/L, and it occurs naturally in deep groundwater, so well systems in the northwest run highest.

Source: EPA UCMR 5 occurrence data (final release, August 2026), samples from 2023 to 2025.

Algal toxins

The water Northwestern W and SD - Sr 108 buys is treated by Napoleon City, so the results below are Napoleon City's.

Ohio EPA tests for microcystin, a toxin that harmful algal blooms can release, in raw water at the intake and in treated water.

At the intake, microcystin was detected 32 times in 266 raw-water samples, across 8 bloom seasons (2016 to 2026); the highest raw-water result was 3.997 µg/L on October 25, 2016. The highest raw-water result since 2024 was 1.316 µg/L.

Microcystin was never detected in treated water (149 samples).

In all, 415 samples from 2016 to 2026, the latest on August 25, 2026.

Microcystin results
WaterSamplesDetectionsHighest result
Raw water, at the intake266323.997 µg/L
Treated water1490not detected

The ten-day advisory levels for treated water are 0.3 µg/L for children under six and 1.6 µg/L for everyone else. Any detection at the intake triggers more frequent testing until two clean weeks.

Source: Ohio EPA public water system harmful algal bloom monitoring, 2016 to present (HAB data, fetched September 2026).

How well the service area is mapped

EPA estimated the service area of Northwestern W and SD - Sr 108 with a computer model rather than drawing it from the utility's map, so its edges are approximate.

Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.

On the map

Show this system's territory on the map — 1 ZIP code in all.

Sources

U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey

EPA's own record for this system: Enforcement and Compliance History report for OH3539214 (EPA ECHO).

Quick answers

Where does Northwestern W and SD - Sr 108 get its water?

Northwestern W and SD - Sr 108 buys its water from Napoleon City.

How many people does Northwestern W and SD - Sr 108 serve?

Northwestern W and SD - Sr 108 serves about 267 people.

Who owns Northwestern W and SD - Sr 108?

Northwestern W and SD - Sr 108 is owned by a local government.

Cite this page

Cite this page as:

Cracked Buckeye, "Northwestern W and SD - Sr 108 · OH3539214", https://crackedbuckeye.com/water/OH3539214/, built 2026-10-31, accessed [date].

How to cite · Report a correction · Built 2026-10-31