Water system

Lake Lucerne Club Co.

EPA ID OH2801512 · Geauga County · 980 people served

Groundwater wells (17 wells)
Groundwater

Lake Lucerne Club Co. treats its own water from Groundwater wells (17 wells).

The system's record

Groundwater wells (17 wells)
Groundwater
Wells: EPA lists 17 active wells. ODNR well logs locate 4 public-supply wells inside Lake Lucerne Club Co.'s wellhead protection zone, 38 to 230 ft deep, in sandstone and shale & sandstone. Zoom in to see them as dots.
Well 2Well 1Well 8Well 9Well 10Well 11Well 12Well 4Well 5Well 6Well 7Well 3Well 15Well 13Well 16Well 14Well 18
Active wells
17
Serves
980 people · Geauga County
EPA ID
OH2801512

About this area's water

Water quality & impurities

EPA compliance record

Lead at the tap: 90th-percentile result 0 ppb in 2025 (action level 15 ppb).

EPA record: no health-based violations since 2015.

Present in 1 ZIP code

Serves

Main water supplier in 1 ZIP code

Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.

Buys from · Sells to

Lake Lucerne Club Co. does not buy water from another system on record; it treats its own source water.

No other system is on record buying water from Lake Lucerne Club Co..

What the records show about Lake Lucerne Club Co.

Who runs it

EPA's record says Lake Lucerne Club Co. has 284 service connections and serves 980 people.

EPA classes it as a community water system, one that serves the same residents all year.

EPA's record says it has substantially implemented source water protection under Ohio's program, dating the program from 2024. Its office telephone on EPA's record is 440-543-5750.

Source: EPA Safe Drinking Water Information System (SDWIS), water system record.

How the water is treated

EPA's treatment table registers these steps for Lake Lucerne Club Co.: corrosion control and chlorine disinfection.

The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.

Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).

Violations

EPA's record shows no health-based violations for Lake Lucerne Club Co. since 2015.

EPA logs no violations of any kind for Lake Lucerne Club Co. since 2020.

Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled September 2026).

Lead and copper at the tap

In the sampling period ending December 2025, the 90th-percentile lead result at Lake Lucerne Club Co. was 0 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027. A result of 0 means at least nine in ten of the homes sampled had no lead detected.

The highest result on file is 3 ppb, in the period ending December 2021.

EPA has 9 sampling periods on file for Lake Lucerne Club Co. since 2016, the first ending in 2017; no period was above 10 ppb.

Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Lake Lucerne Club Co. sent EPA, 282 lines are counted.

Service lines in the inventory
MaterialLines
Lead0
Galvanized, needing replacement0
Unknown material0
Not lead282
All lines282

Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.

EPA's dashboard status for this inventory: reported all required service line types.

Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.

PFAS

Ohio EPA's own statewide sampling tested 5 plants of Lake Lucerne Club Co. (latest sample June 2020). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.

Ohio EPA's current sampling status map lists 5 plants of Lake Lucerne Club Co. as sampled, most recently February 2026.

PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.

Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.

Disinfection byproducts

Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.

For TTHM, the average of Lake Lucerne Club Co.'s samples in 2019, the last year it was sampled, was 4.4 µg/L. The worst yearly average was 8.9 µg/L and the highest single sample was 20.9 µg/L, from 19 samples taken from 2012 to 2019.

For HAA5, the average in the last year sampled was 4.6 µg/L. The worst yearly average was 7.5 µg/L and the highest single sample was 15 µg/L, from 19 samples.

Disinfection byproducts in the distribution system
ByproductLimitLatest yearly averageWorst yearly averageHighest sampleSamples
TTHM80 µg/L4.4 µg/L (2019)8.9 µg/L20.9 µg/L19
HAA560 µg/L4.6 µg/L7.5 µg/L15 µg/L19

A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).

Nitrate, arsenic and radioactivity

Nitrate: the highest of 40 samples was 3.4 mg/L (as nitrogen) in 2012; in 2019, the last year sampled, the highest was 2.91 mg/L. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.

Arsenic: the highest of 10 samples was 2 µg/L (limit 10); detections averaged 2; none over the limit.

Nitrate, arsenic and radioactivity in finished water, 2012 to 2019
ContaminantSamplesHighest resultLimitSamples over limit
Nitrate (as nitrogen)403.4 mg/L10 mg/L0
Arsenic102 µg/L10 µg/L0
Combined radium46.4 pCi/L5 pCi/L1

Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Solvents and fuels

EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 10 samples each.

Solvents and fuels in finished water, 2012 to 2019
CompoundLimitSamplesDetected inHighest resultSamples over limit
Benzene5 µg/L100 of 10not detected0
Carbon tetrachloride5 µg/L100 of 10not detected0
1,2-dichloroethane5 µg/L100 of 10not detected0
Trichloroethylene (TCE)5 µg/L100 of 10not detected0
Tetrachloroethylene (PCE)5 µg/L100 of 10not detected0
Vinyl chloride2 µg/L100 of 10not detected0

"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Farm chemicals and metals

EPA's file holds results for all nine herbicides and metals it checked. Detected: barium in 7 of 10 samples, highest 530 µg/L (limit 2,000). Not detected: atrazine in 15 samples, alachlor in 15 samples, 2,4-D in 4 samples, chromium in 10 samples, cadmium in 10 samples, mercury in 10 samples, selenium in 10 samples, thallium in 10 samples.

Herbicides and metals in finished water, 2012 to 2019
SubstanceKindLimitSamplesDetected inHighest resultSamples over limit
AtrazineFarm chemical3 µg/L150 of 15not detected0
AlachlorFarm chemical2 µg/L150 of 15not detected0
2,4-DFarm chemical70 µg/L40 of 4not detected0
ChromiumMetal100 µg/L100 of 10not detected0
CadmiumMetal5 µg/L100 of 10not detected0
BariumMetal2,000 µg/L107 of 10530 µg/L0
MercuryMetal2 µg/L100 of 10not detected0
SeleniumMetal50 µg/L100 of 10not detected0
ThalliumMetal2 µg/L100 of 10not detected0

Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Bacteria in the pipes

From 2012 to 2019, 1 of 281 routine total coliform samples taken in the distribution system at Lake Lucerne Club Co. tested positive (0.36%); in 2019, the last year on file, 0 of 12 did. E. coli was never found in the 231 samples tested for it.

A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.

Fluoride

The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Lake Lucerne Club Co. draws on more than one source, and the blend keeps fluoride at the recommended level.

EPA's treatment table lists no fluoridation step at Lake Lucerne Club Co.

Measured fluoride: 0.45 mg/L on average at the plant's entry points in 2017 (below the 0.7 mg/L target), with 2 of that year's samples below the 0.2 mg/L reporting limit and left out of the average; samples ran from 0.2 to 0.92 mg/L across 10 samples in 2012 to 2019.

The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.

Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.

How well the service area is mapped

EPA estimated the service area of Lake Lucerne Club Co. with a computer model rather than drawing it from the utility's map, so its edges are approximate.

Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.

On the map

Show this system's territory on the map — 1 ZIP code in all.

Sources

U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey

EPA's own record for this system: Enforcement and Compliance History report for OH2801512 (EPA ECHO).

Quick answers

Where does Lake Lucerne Club Co. get its water?

Lake Lucerne Club Co. treats its own water from Groundwater wells (17 wells).

How many people does Lake Lucerne Club Co. serve?

Lake Lucerne Club Co. serves about 980 people, and is the main water system for 1 ZIP code.

Cite this page

Cite this page as:

Cracked Buckeye, "Lake Lucerne Club Co. · OH2801512", https://crackedbuckeye.com/water/OH2801512/, built 2026-10-31, accessed [date].

How to cite · Report a correction · Built 2026-10-31