Water system

Upper Sandusky City

EPA ID OH8800511 · Wyandot County · 6,698 people served · owned by a local government

Sandusky River (via Upper Sandusky Reservoirs 1 & 2)
Inland river

Upper Sandusky City treats its own water from Sandusky River (via Upper Sandusky Reservoirs 1 & 2).

The system's record

Sandusky River (via Upper Sandusky Reservoirs 1 & 2)
Inland river
Water bodies
Sandusky River, Upper Sandusky Reservoir 1, Upper Sandusky Reservoir 2
Raw intakes
Reservoir
Sandusky River Reservoir
Serves
6,698 people · Wyandot County
EPA ID
OH8800511

About this area's water

Historic postcard view of the Sandusky River at Upper Sandusky, Ohio
Historic postcard view of the Sandusky River at Upper Sandusky, OhioPhoto: This file was contributed to Wikimedia Commons by Columbus Metropolitan Library , Public domain · Wikimedia Commons
Did you know
  • Upper Sandusky ran the same lime-softening water plant from 1890 until the last decade or so - by the time engineers evaluated it, parts were close to 120 years old and it sat in the river's flood plain.
  • Its replacement runs ultrafiltration plus reverse osmosis, a train more typical of seawater desalination than of a city of under 7,000, chosen to strip more than 90 percent of the organics that drive disinfection…
  • The city still has eight combined sewer overflows discharging to the same Sandusky River it drinks from, and files 4-hour and 7-day public notices each time one runs.
  • Anyone can buy water at the city's bulk station, and filling a swimming pool costs $16.50 per 1,000 gallons plus labor.

Source: aecom.comuppersanduskyoh.comuppersanduskyoh.com

History2
  • 1890City built a lime-softening water treatment plant, sited in the Sandusky River flood plain; it remained in service for well over a century, with components described as nearly 120 years old when…
  • undatedCity replaced the 1890 lime-softening plant with a 21,000-square-foot integrated membrane treatment plant (ultrafiltration plus reverse osmosis) designed by AECOM, driven by tightening disinfection…

Source: aecom.com

Treatment & pressure

How it is treated

Raw water is pumped from the Sandusky River into the city's reservoir(s) for storage - the 2024 CCR names Reservoir #2 - and then treated. AECOM describes the replacement plant as a 21,000-square-foot integrated membrane facility combining ultrafiltration and reverse osmosis, achieving greater than…

Source: aecom.comuppersanduskyoh.com

Water pressure

Not published. No pressure figures, hydraulic model, or pressure-zone map could be found in the city's CCRs, water and sewer pages, or public works pages.

What it costs

$10.50 per 1,000 gallons

Typical household bill about $67 a month for water.

City-published schedule: water consumption $10.50 per 1,000 gallons with a $21.00 per month minimum consumption charge, plus a separate monthly meter unit charge - $25.00 for a…

Source: uppersanduskyoh.com

Water quality & impurities10
ContaminantLevelLimitYear
Total trihalomethanes (TTHM)
Range of detections 33.6 to 83.8 ppb; individual samples exceeded 80 ppb but compliance is on a locational running…
61.4 ppb80 ppb MCL2024
Haloacetic acids (HAA5)
Range 18.2 to 34.0 ppb.
26.9 ppb60 ppb MCL2024
Nitrate
Range <1.0 to 3.13 ppm; agricultural runoff in the Sandusky River watershed.
3.13 ppm10 ppm MCL2024
Atrazine
Runoff from herbicide used on row crops.
0.083 ppb3 ppb MCL2024
Fluoride
Range 0.87 to 1.22 ppm.
1.22 ppm4 ppm MCL2024
Copper
Range <0.01 to 0.7 ppm; all 20 samples below the action level.
0.11 ppm1.35 ppm action…2024
Lead
Range <2.0 to 2.8 ppb; all 20 samples below the action level.
<2.0 ppb15.5 ppb action…2024
Chlorine
Range 1.33 to 1.57 ppm.
1.48 ppm4 ppm MRDL2024
Turbidity
Highest recorded value 0.14 NTU; 100 percent of samples met the standard.
0.14 NTUtreatment…2024
Total organic carbon (TOC)
Range 1.61 to 2.10 mg/L.
2.10 mg/Ltreatment…2024

Source: uppersanduskyoh.com

EPA compliance record

Lead at the tap: 90th-percentile result 0 ppb in 2025 (action level 15 ppb).

EPA record: no health-based violations since 2015.

1 violation of any kind logged since 2020: 1 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).

Projects & plans1

Recent and current work

  • Integrated membrane water treatment plant (ultrafiltration plus reverse osmosis) · unknown · completed
    21,000 square feet; replaced the 1890 lime-softening plant sited in the Sandusky River flood plain, to meet disinfection byproduct rules. Designed by AECOM…

Source: aecom.com

Supply stress

The Ohio EPA source water assessment treats all surface waters as susceptible to contamination, and names the specific threats to Upper Sandusky's protection area: agricultural runoff from fields and feedlots, commercial and industrial sources, leaking underground and aboveground storage tanks, home construction runoff, and quarry…

Source: uppersanduskyoh.com

Sewers

Sanitary

City-operated wastewater treatment plant at 155 Indian Mill Drive, discharging to the Sandusky River under US EPA permit OH0020001 and Ohio EPA permit 2PD000039. Sewer is billed at $14.50 per 1,000 gallons with a $29.00 monthly minimum.

Storm

Partly combined. The city has eight combined sewer overflows that discharge to the Sandusky River and its tributaries, and posts 4-hour and 7-day CSO notices plus an annual CSO notification report under the US EPA's January 2018 public notification rule…

Source: uppersanduskyoh.comuppersanduskyoh.com

Sourcesverified

Compiled from the utility's own reports and public records, then independently re-checked against primary sources.

Main supplier in 1 ZIP code

Serves

Main water supplier in 1 ZIP code

Population-weighted resident shares; a ZIP code can have more than one system on record. Recomputed from each ZIP's own system list, not from the map's cached footprint.

Buys from · Sells to

Upper Sandusky City does not buy water from another system on record; it treats its own source water.

No other system is on record buying water from Upper Sandusky City.

What the records show about Upper Sandusky City

Who runs it

EPA's record describes Upper Sandusky City as owned by a local government. It has 2,935 service connections and serves 6,698 people.

EPA classes it as a community water system, one that serves the same residents all year.

Its office telephone on EPA's record is 419-294-3862.

Source: EPA Safe Drinking Water Information System (SDWIS), water system record.

How the water is treated

EPA's treatment table registers these steps for Upper Sandusky City: corrosion control, cartridge filtration, coagulation and settling, chlorine disinfection, dechlorination, iron and manganese removal, fluoridation, membrane filtration, and powdered activated carbon.

The list is what each system registered with EPA for treatment plants EPA still shows as active, and it can lag a plant upgrade.

Source: EPA Safe Drinking Water Information System (SDWIS) treatment table (EPA Envirofacts, pulled September 2026).

Violations

EPA's record shows no health-based violations for Upper Sandusky City since 2015.

EPA logs 1 violation of any kind since 2020: 1 for a report, record or notice that was missing, late or incomplete (the yearly water quality report, a public notice, lead line records).

Source: EPA Safe Drinking Water Information System (SDWIS) violation records: health-based violations with compliance periods beginning in 2015 or later, all violations from 2020 or later (EPA Envirofacts, pulled September 2026).

Lead and copper at the tap

In the sampling period ending December 2025, the 90th-percentile lead result at Upper Sandusky City was 0 ppb, under both the current 15 ppb action level and the 10 ppb level that applies from 2027. A result of 0 means at least nine in ten of the homes sampled had no lead detected.

EPA has 6 sampling periods on file for Upper Sandusky City since 2016, the first ending in 2018; no period was above 10 ppb.

Every water system has to inventory its service lines, the pipes from the main to each building. In the inventory Upper Sandusky City sent EPA, 2,789 lines are counted.

Service lines in the inventory
MaterialLines
Lead0
Galvanized, needing replacement93
Unknown material218
Not lead2,478
All lines2,789

Systems sample taps in the homes most likely to have lead pipes or solder. The 90th-percentile result is the level nine in ten of the sampled homes were at or below. Lead comes mostly from service lines and house plumbing, not the source water, so a low result for the system does not clear an old house.

EPA's dashboard status for this inventory: reported all required service line types.

Source: EPA Safe Drinking Water Information System (SDWIS) lead and copper 90th-percentile results (EPA Envirofacts), sampling periods ending 2016 or later; EPA's service line inventory dashboard, Ohio's 2026 Q2 submission.

PFAS

EPA's fifth national round of testing (UCMR 5) took 6 samples of the water entering the pipes of Upper Sandusky City in 2025 to 2026 and measured 29 PFAS. No PFAS was detected, PFOA and PFOS (federal limit 4 ng/L each) among them.

Ohio EPA's own statewide sampling tested 1 plant of Upper Sandusky City (latest sample October 2020). Not one of the six PFAS tested (PFOA, PFOS, PFHxS, PFNA, GenX and PFBS) was detected.

PFAS are the 'forever chemicals' from firefighting foam, plating shops and non-stick coatings. Results are for water leaving the plant, not your tap.

Source: EPA UCMR 5 occurrence data (final release, August 2026); Ohio EPA statewide PFAS sampling, 2019 to 2021, and its sampling status map.

Disinfection byproducts

Chlorine that disinfects water also reacts with organic matter to form byproducts. Two groups have federal limits: total trihalomethanes (TTHM, 80 µg/L) and five haloacetic acids (HAA5, 60 µg/L), judged on running yearly averages at each sampling site.

For TTHM, the average of Upper Sandusky City's samples in 2019, the last year it was sampled, was 55.7 µg/L. The worst yearly average was 63.3 µg/L and the highest single sample was 99.5 µg/L, from 72 samples taken from 2012 to 2019.

For HAA5, the average in the last year sampled was 24.5 µg/L. The worst yearly average was 29.6 µg/L and the highest single sample was 56.6 µg/L, from 70 samples.

Disinfection byproducts in the distribution system
ByproductLimitLatest yearly averageWorst yearly averageHighest sampleSamples
TTHM80 µg/L55.7 µg/L (2019)63.3 µg/L99.5 µg/L72
HAA560 µg/L24.5 µg/L29.6 µg/L56.6 µg/L70

A yearly average of 0 means nothing was detected in that year's samples. EPA's file stops at 2019; Ohio EPA's Drinking Water Watch has newer results.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system samples (non-detects counted as zero).

Nitrate, arsenic and radioactivity

Nitrate: the highest of 96 samples was 0.75 mg/L (as nitrogen) in 2013; in 2019, the last year sampled, the highest was 0.27 mg/L. No sample was over the limit of 10 mg/L. Nitrate above 10 is unsafe for infants.

Arsenic was not detected in 8 samples (limit 10 µg/L).

Nitrate, arsenic and radioactivity in finished water, 2012 to 2019
ContaminantSamplesHighest resultLimitSamples over limit
Nitrate (as nitrogen)960.75 mg/L10 mg/L0
Arsenic8not detected10 µg/L0

Measured in finished water: at the plant's entry points and in the distribution system; raw well and intake samples are left out. Non-detects count as zero.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Solvents and fuels

EPA's file holds results for all six solvent and fuel compounds it checked. Benzene, carbon tetrachloride, 1,2-dichloroethane, trichloroethylene, tetrachloroethylene, and vinyl chloride were not detected in 9 samples each.

Solvents and fuels in finished water, 2012 to 2019
CompoundLimitSamplesDetected inHighest resultSamples over limit
Benzene5 µg/L90 of 9not detected0
Carbon tetrachloride5 µg/L90 of 9not detected0
1,2-dichloroethane5 µg/L90 of 9not detected0
Trichloroethylene (TCE)5 µg/L90 of 9not detected0
Tetrachloroethylene (PCE)5 µg/L90 of 9not detected0
Vinyl chloride2 µg/L90 of 9not detected0

"Not detected" means the lab's result was below what its method can measure, not that the compound is absent. Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Farm chemicals and metals

EPA's file holds results for 8 of the nine herbicides and metals it checked. Detected: atrazine in 12 of 15 samples, highest 0.21 µg/L (limit 3); barium in 7 of 8 samples, highest 19 µg/L (limit 2,000). Not detected: alachlor in 15 samples, chromium in 8 samples, cadmium in 8 samples, mercury in 8 samples, selenium in 8 samples, thallium in 8 samples.

Herbicides and metals in finished water, 2012 to 2019
SubstanceKindLimitSamplesDetected inHighest resultSamples over limit
AtrazineFarm chemical3 µg/L1512 of 150.21 µg/L0
AlachlorFarm chemical2 µg/L150 of 15not detected0
ChromiumMetal100 µg/L80 of 8not detected0
CadmiumMetal5 µg/L80 of 8not detected0
BariumMetal2,000 µg/L87 of 819 µg/L0
MercuryMetal2 µg/L80 of 8not detected0
SeleniumMetal50 µg/L80 of 8not detected0
ThalliumMetal2 µg/L80 of 8not detected0

Non-detects count as zero in the highest-result column.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, finished water.

Bacteria in the pipes

From 2012 to 2019, 7 of 673 routine total coliform samples taken in the distribution system at Upper Sandusky City tested positive (1.04%); in 2019, the last year on file, 1 of 84 did. E. coli was found in 1 of 7 samples tested for it.

A positive coliform test is a warning sign, not a violation by itself. E. coli is a sign that human or animal waste may have reached the water. Coliform counts are routine samples only; E. coli counts include repeat samples.

Source: EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, distribution-system presence/absence tests for total coliform and E. coli.

Fluoride

The Ohio Department of Health's report to the CDC (My Water's Fluoride) says Upper Sandusky City adjusts the fluoride level to the recommended level for preventing tooth decay.

EPA's treatment table lists fluoridation among the steps at Upper Sandusky City.

Measured fluoride: 0.98 mg/L on average at the plant's entry points in 2019 (in the range dentists aim for); samples ran from 0.87 to 1.12 mg/L across 8 samples in 2012 to 2019.

The recommended level for preventing tooth decay is 0.7 mg/L; the federal limit is 4 mg/L. The treatment list is what each system registered with EPA and can lag a plant upgrade.

Source: CDC My Water's Fluoride (fluoridation status as reported by the Ohio Department of Health, fetched September 2026); EPA Safe Drinking Water Information System (SDWIS) treatment table; EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, entry-point fluoride samples.

Lithium

Lithium was not detected in 4 UCMR 5 samples at Upper Sandusky City, last sampled in 2025 (the method reports from 9 µg/L).

Lithium is not regulated. EPA's draft health reference level is 10 µg/L, and it occurs naturally in deep groundwater, so well systems in the northwest run highest.

Source: EPA UCMR 5 occurrence data (final release, August 2026), samples from 2023 to 2025.

Algal toxins

Ohio EPA tests for microcystin, a toxin that harmful algal blooms can release, in raw water at the intake and in treated water.

At the intake, microcystin was detected 7 times in 223 raw-water samples, across 1 bloom season (2022); the highest raw-water result was 4.3 µg/L on July 26, 2022. There has been no raw-water detection since 2024.

Microcystin was never detected in treated water (85 samples).

In all, 308 samples from 2016 to 2026, the latest on August 25, 2026.

Microcystin results
WaterSamplesDetectionsHighest result
Raw water, at the intake22374.3 µg/L
Treated water850not detected

The ten-day advisory levels for treated water are 0.3 µg/L for children under six and 1.6 µg/L for everyone else. Any detection at the intake triggers more frequent testing until two clean weeks.

Source: Ohio EPA public water system harmful algal bloom monitoring, 2016 to present (HAB data, fetched September 2026).

How well the service area is mapped

The service area drawn on the map for Upper Sandusky City comes from the utility's own map.

Counting the people who live in the ZIP codes it overlaps, this atlas estimates 6,338 residents are inside the boundary, 95% of the 6,698 people Upper Sandusky City reports serving.

The resident count is an estimate from 2020 Census ZIP-code populations, not a count of customers.

Source: EPA Service Area Boundaries; resident estimate by this atlas from ZIP-code overlap.

Photograph

Historic postcard view of the Sandusky River at Upper Sandusky, Ohio
Historic postcard view of the Sandusky River at Upper Sandusky, OhioPhoto: This file was contributed to Wikimedia Commons by Columbus Metropolitan Library · Public domain · Wikimedia Commons

On the map

Show this system's territory on the map — 1 ZIP code in all.

Sources

U.S. EPA SDWIS and Community Water System Service Area Boundaries (v3, 2026), Ohio EPA primacy data, 2020 census blocks: the system serving most residents, traced through purchases to the treating utility; Ohio EPA 2023 Sewer and Water Rate Survey (Ohio State, May 2025) for household bills; Ohio EPA DEFA loan awards since 2016 for the loans paragraph · EPA SDWIS · EPA service area boundaries · Ohio EPA drinking water · Ohio EPA rate survey

EPA's own record for this system: Enforcement and Compliance History report for OH8800511 (EPA ECHO).

Upper Sandusky City's own pages: aecom.com

Notable facts: aecom.com, uppersanduskyoh.com, uppersanduskyoh.com

History: aecom.com

Water quality: uppersanduskyoh.com

Capital projects: aecom.com

Rates: uppersanduskyoh.com

Sewers: uppersanduskyoh.com, uppersanduskyoh.com

Treatment: aecom.com, uppersanduskyoh.com

Supply stress: uppersanduskyoh.com

Quick answers

Where does Upper Sandusky City get its water?

Upper Sandusky City treats its own water from Sandusky River (via Upper Sandusky Reservoirs 1 & 2).

How many people does Upper Sandusky City serve?

Upper Sandusky City serves about 6,698 people, and is the main water system for 1 ZIP code.

Who owns Upper Sandusky City?

Upper Sandusky City is owned by a local government.

Is there lead in Upper Sandusky City water?

In 2024 testing, Upper Sandusky City's 90th-percentile lead level in tap samples was <2.0 ppb (the federal action level is 15.5 ppb). Range <2.0 to 2.8 ppb; all 20 samples below the action level.

How much fluoride is in Upper Sandusky City water?

Upper Sandusky City reported fluoride at 1.22 ppm in 2024. Range 0.87 to 1.22 ppm.

Cite this page

Cite this page as:

Cracked Buckeye, "Upper Sandusky City · OH8800511", https://crackedbuckeye.com/water/OH8800511/, built 2026-10-31, accessed [date].

How to cite · Report a correction · Built 2026-10-31